Access to IMMS tools and features is controlled by User Permissions. All features may not be accessible by all Users. Contact your Instance Administrator regarding User Permissions. |
IMMS maintains a Device/Equipment List with a details record for every System Element (e.g., device) within the System design.
System Elements can be populated or updated via bulk-data entry using the IMMS Import feature. This document will serve as a guide for the bulk creation or bulk update of System Elements in IMMS.
When importing bulk System Element data, you will use the Import System Elements/Assets form. While bulk Asset imports are typically created/updated via the Import Assets form (see "Assets Import" section), the bulk import of System Elements data may include the creation or update of Assets that are associated with the created/updated System Elements.
See “Asset Definition” under the Assets and Inventory Management section for more information on the relationship between System Elements and Assets.
For the bulk creation of System Elements in IMMS, the data to be imported must be contained in a properly formatted CSV file.
Since a System Elements Import can include System Element information as well as information for any associated Asset, IMMS requires the following naming convention for certain column headers:
Prefix | Description |
D_ | Identifies a System Element (e.g., Device) attribute |
A_ | Identifies an Asset attribute |
Note:
The Action column header does not require a prefix, as the Import action is related to the System Element and the same action will be applied to any imported Asset information.
A Location column header does not require a prefix, as the Location for a listed System Element would automatically apply to any Asset associated with that System Element. The Location field value should be the Location path, with each path segment separated by a backward slash (e.g., “Building A\Floor 2\Room 231”).
The following data columns (i.e., column headers) are required and must be populated for each line when creating System Elements:
Optional data columns may include:
|
Note: Optional data columns may also include one or more columns for Custom Field values, with the column header reflecting the appropriate Custom Field name.
When creating System Elements via a bulk data import, you can simultaneously create a new Asset if the Asset is associated with a new System Element.
When creating a new Asset, the following data column headers are required:
For the bulk update of System Elements in IMMS, the data to be imported must be contained in a properly formatted CSV file.
Since a System Elements Import can include System Element information as well as information for any associated Asset, IMMS requires the following naming convention for certain column headers:
Prefix | Description |
D_ | Identifies a System Element (e.g., Device) attribute |
A_ | Identifies an Asset attribute |
Note:
The Action column header does not require a prefix, as the Import action is related to the System Element and the same action will be applied to any imported Asset information.
A Location column header does not require a prefix, as the Location for a listed System Element would automatically apply to any Asset associated with that System Element. The Location field value should be the Location path, with each path segment separated by a backward slash (e.g., “Building A\Floor 2\Room 231”).
The following data columns (i.e., column headers) are required and must be populated for each line when updating a System Elements via bulk data import.
When updating System Elements via a bulk data import, you can simultaneously update certain attributes of an Asset deployed against a listed System Element. Optional data columns should include column headers for all System Element ("D_xxx") or Asset ("A_xxx") attributes to be updated with your Import.
Note: Some attributes of a Deployed Asset (e.g., Location, Status) are dictated by the System Element association. Therefore, you will never include those Asset-specific data columns (e.g., "A_Location", A_Status) within the data file for a System Element Import.
When updating bulk records via the Import feature, Users typically start the process by exporting the applicable records from IMMS. See the Exporting Data for Update section for more information. |
Whether you are creating new System Elements or updating existing System Elements in IMMS, you will follow these steps for importing the bulk data.
Click on the Main Menu button at the top of the screen. From the “Configuration Baseline” section of the Main Menu, select “Device/Equipment List”. This will open the Device/Equipment List view.
Click on the button at the top of the view.
From the Import drop-down menu, select the “System Elements” option. An “Import System Elements/Assets” form will pop up. From the Import System Elements/Assets form, you will:
Once all form fields are populated, click the OK button at the bottom of the form.
Note: Default values entered in an Import form will be overridden by any explicit value provided within the data file for that same attribute. That is, the form’s default value will only be applied if there is no such value provided for a System Element or Asset within the Import data file.
Custom Fields associated with a System Element can support a number of different data types, such as text, numeric, date/time, image files, etc. Custom Field values that require a file upload can be populated via bulk-data entry using the Import-Files feature for System Elements.
First, create a single ZIP file that contains all the files you wish to upload. The ZIP file can contain folders and subfolders. IMMS will extract and process all files.
The ZIP file may also contain a mapping file. A mapping file is a CSV file that includes instruction for the files being uploaded. If you are using a mapping file, the file should be named “Import File List.csv”. The mapping file will include three data columns and a line entry for each file being uploaded. The column headers include:
Note: Zipped Custom Field(s) file must have Import File List.cvs in its root folder. To create ZIP file do not compress folder containing Import File List.cvs file, instead select Import File List.cvs file and applicable files/folders and compress them.
From the Device/Equipment List view, click on the button at the top of the page. Select “Files” from the drop-down menu.
This will open the Import Files form. From this form, you will:
If there are any errors in the Import data file, IMMS will alert you of these exceptions and reject the entire Import. That is, IMMS will not partially process an Import.
All exceptions must be corrected in the data file before it can be imported. Correct exceptions in all specified line items and then repeat the Import steps listed above.
If IMMS identifies no exceptions within the data file, your bulk data will be successfully imported, and IMMS will return you to the view where you initiated your Import. The view should then include your new or updated records. The Import will also be listed in the Successfully Completed Imports list accessible via the "Show Completed" option under the Import button drop-down menu.